Fire Alarm Systems
- fire-alarm-systems-fixed-gas
Addressable fire alarm control panel with 1 loop. Up to of 100 addresses (detectors, modules, sounders or manual call points) with the loop. Self-search and self-diagnosis functions. 250 programmable zones, 20 alarm and fault led display zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. ABS plastic casing for wall mounting and even prepared to be embedded into it. Multilingual keyboard. Able to be networked (F-Network or S-Network) up to 32 control panels o repeaters via RS485 or fiber optics. Modbus output for integrations and Contact ID for connection to CMS (optional). Full remote access of the panel if a TED-151-CL card (Detnov Cloud) is added. CPR certificate EN 54-2, EN 54-4. Requires 2 BTD-1207 batteries not included. Dimensions: 430 x 268 x 109 mm.
Conventional optical smoke detector. Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
Addressable optical smoke detector, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
Conventional optical and heat detector. Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
Addressable optical & heat detector, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
Conventional heat detector (58°C fixed temperature and 8ºC/min thermal rate of rise). Led status indicator and output for remote pilot indicator PAD-10. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm. Download Datasheet
Addressable manual call point. LED status indicator and test key. Allows installation without polarity. Red color. CPR certificate EN54-11. Dimensions: 98 x 98 x 48 mm.
Addressable manual call point IP67 with built-in isolator. Suitable for outdoor applications. LED status indicator and test key. Red color. Dimensions: 119 x 128 x 62 mm.
Addressable loop sounder with built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power from 78.3 dBA to 104.6 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
Conventional manual call point, with test key, for surface installation. Suitable for indoor. Red color. Includes resistance of 100 Ohm.-2W. Dimensions: 98 x 98 x 48 mm. CPR certificate EN54-11.