Conventional manual call point, with test key, for surface installation. Suitable for indoor. Red color. Includes resistance of 100 Ohm.-2W. Dimensions: 98 x 98 x 48 mm. CPR certificate EN54-11.
Release manual call point. Yellow color. With test key, surface mount. Protective plastic cover included. Use for indoor applications. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.
Abort manual call point. Color blue. With test key, surface mount. Protective plastic cover included. Indoor use. Includes resistance of 100 Ohm -2W. Dimensions: 98 x 98 x 48 mm.
Bidirectional repeater for Detnov addressable CAD-150 series. Allows the remote supervision control of control panels networked (F-Network) up to 32 nodes. It shows the same incidences reflected in the control panel. It can be added in ring or bus networks configurations. LCD display and 4 control keys (reset, mute buzzer, mute sounders and activate sounders). Includes RS485 communication card (TRED-150). ABS plastic casing for wall mounting and even prepared to be embedded into it. Requires 230Vac and 2 batteries BTD-1207 (not included). Dimensions: 443 x 268 x 109 mm.
Indoor alarm sounder. 32 selectable tones. Power at 24Vdc / 7mA at 32mA according to tone. IP21. Red color. Acoustic power 95 up to 100 dB according to tone. CPR certificate EN54-3. Dimensions: 85×75 mm.
Advanced design and innovative features make the 9010 and 9020 Controllers the top choice for gas-warning systems, monitoring up to 20 channels. The 9010 Controller operates with one independent sensor, while the 9020 operates with two independent sensors per control module. Each module comes with an independent AC/DC power supply for increased system reliability. Both units feature full internal diagnostics, which minimize false alarms and unexpected down time. The controllers can also power remote sensors, while the large four-digit LCD and LED provide such crucial information as gas concentration, alarm status and more. A convenient RS-485 serial interface offers handy printer connection to make a record of data, while a customized transmission protocol Modbus RTU can record serial bus data transmission such as system configuration, gas concentration, alarm and failure events.
Safely and reliably detect ammonia gas leaks
The Chillgard 5000 Ammonia Monitor accurately detects ammonia gas leaks as low as 10 ppm for early notification, keeping your plant safe according to ANSI/IIAR and EN 378. Using Photoacoustic Infrared (PAIR) technology provides a more accurate measurement and requires less maintenance than traditional electrochemical gas sensors for lower cost of ownership.The Chillgard 5000 Refrigerant Leak Monitor provides the earliest level of detection of costly refrigerant gas leaks in mechanical equipment rooms. Sampling system with patented photoacoustic infrared (PAIR) technology detects leaks as low as 1 part per million (ppm). Intuitive, touchscreen user interface makes it easy to operate. Predictive maintenance and diagnostics keep you operational.
The FL500 Ultraviolet / Infrared Flame Detector delivers high speed flame detection with increased false alarm immunity in a compact design
The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.Instantly detect pressurized gas leaks with this high-precision, omni-direction acoustic detector utilizing Gassonic® ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. The Observer-i UGLD provides an industry-leading detection range (up to 28 m) reducing the number of detectors required.
- Ideal for use in complex, outdoor pipeline systems - unaffected by wind, gas dilution, and direction of gas plume.
- Artificial Neural Network (ANN) technology distinguishes real gas leak noise from background noise, suppressing false alarm sources.
- Does not require in-field training, fully operational after installation.
- Detects gas leaks from 2 BAR (29 psi) pressure for rapid detection of small gas leaks.
- Patented Senssonic™ self-test function ensures full fail-safe operation.
- Trouble-free maintenance and one-person check and calibration.
General Monitors® S5000 Gas Monitor
The General Monitors S5000 Gas Monitor is the ultimate gas detector for extreme environments needing to detect oxygen, toxic and combustible gases
It operates over a wide temperature range using a variety of gas sensing technologies. Breakthrough XCell® gas sensors with TruCal® technology extends calibration cycles up to 24 months and actively monitors sensor integrity for ultimate peace of mind.
The IR5500 is an open path infrared (IR) gas detector that continuously monitors for flammable gas leaks over large open areas. It monitors in both the LEL-m and ppm-m ranges to detect both small and large leaks. The IR5500 offers the benefits of early detection with its high sensitivity to gas concentrations at the ppm levels. This feature allows it to alarm faster than an LEL-only detector. Digital display and adjustable mounting arms ensure easy alignment. Factory calibrated for low-maintenance operation.