Detnov SCD-200 Indoor alarm sounder with 32 selectable tones
October 22, 2023
Detnov PCD-100 Conventional manual call point
October 22, 2023Detnov MAD-465-I Addressable loop sounder with beacon and built-in isolator
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
Related products
-
MSA General Monitors FL500 UV/IR Flame Detector
The FL500 Ultraviolet / Infrared Flame Detector delivers high speed flame detection with increased false alarm immunity in a compact design
The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. This UV/IR combination provides a fast response time and increased false alarm immunity against sources of radiation for reliable protection.
-
MSA Ultima® X Series Gas Monitors
Ultima® X Series Gas Monitors
Ultima X Series Gas Detector for indoor or outdoor continuous monitoring of hazardous gases.
Designed to provide thorough, continuous monitoring of many hazardous gases, the indoor/outdoor Ultima X Series Gas Monitors offer excellent performance and MSA quality craftsmanship. DuraSource™ Technology offers extended sensor life, while HART provides convenient setup, calibration and diagnostics. HART also allows for existing component install and wiring to be used. A single circuit board increases reliability, while our patented sensor disconnect-underpower feature allows all sensors to be replaced in hazardous areas without area declassification.
-
MSA 9010/9020 LCD
Advanced design and innovative features make the 9010 and 9020 Controllers the top choice for gas-warning systems, monitoring up to 20 channels. The 9010 Controller operates with one independent sensor, while the 9020 operates with two independent sensors per control module. Each module comes with an independent AC/DC power supply for increased system reliability. Both units feature full internal diagnostics, which minimize false alarms and unexpected down time. The controllers can also power remote sensors, while the large four-digit LCD and LED provide such crucial information as gas concentration, alarm status and more. A convenient RS-485 serial interface offers handy printer connection to make a record of data, while a customized transmission protocol Modbus RTU can record serial bus data transmission such as system configuration, gas concentration, alarm and failure events.






Reviews